SHAREWAY TECHNOLOGY CO., LTD.

Share Our Successful Way With You

Manufacturer from China
Verified Supplier
8 Years
Home / Products / SMPS Flyback Transformer /

750316031 Horizontal Installation CCFL Inverter Transformer 150KHz Min Frequency

Contact Now
SHAREWAY TECHNOLOGY CO., LTD.
Visit Website
Country/Region:china
Contact Person:MrNick Chou
Contact Now

750316031 Horizontal Installation CCFL Inverter Transformer 150KHz Min Frequency

Ask Latest Price
Brand Name :Shareway
Model Number :750316031
Certification :CE UL RoHS ISO9001:2008
Place of Origin :Guangdong China
MOQ :100/500/1000
Price :Supportive
Payment Terms :TT,Paypal, Western Union
Supply Ability :3000K.PCS/Month
Delivery Time :Stock or 3 weeks
Packaging Details :Tray, Tape or Reel
Product name :750316031 Horizontal Installation SMPS Flyback Transformer For CCFL inverter
Application :CCFL inverter
Standard :IEC/JIS/NEMA
Material :Copper Winding
Coil Number :Autotransformer
Coil Structure :Toroidal
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

750316031 Horizontal Installation SMPS Flyback Transformer For CCFL inverter


ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted:

PARAMETER TEST CONDITIONS VALUE
D.C. RESISTANCE 1-3 @20°C 0.160 ohms max
D.C. RESISTANCE 6-4 @20°C 0.350 ohms max
INDUCTANCE 1-3 100KHz,10mVAC,Ls 370uH min.
DIELECTRIC 1-6 6250vac,1 second 5000Vrms, 1 minute
TURNS RATIO (6-4):(1-3) 1.75:1±2%

GENERAL SPECIFICATIONS:

  • OPERATING TEMPERATURE RANGE: -40°C TO +85°C .
  • CURRENT RATING: 1A
  • VOLTAGE-TIME: 23Vus
  • SWITCHING FREQUENCY: 150KHz min.
  • 11mm min. creepage and clearance between PRI & SEC.
  • COPLANARITY: All 6 terminals must lie on a plane within .004[.10] of Surface A after leaf tinning,
  • Designed to comply with the following requirements as defined by IEC60601-1(ed): Amendment 1: -Providing two means of Patient Protection up to a working voltage of 360VAC.
  • Complies with the following requirements as defined by IEC60950-1, EN60950-1, UL60950-1/CSA60950-1 and AS/NZS60950-1: -Reinforced insulation for a primary circuit at a working voltage of 55-VAC, overvoltage Category II,Pollution Degree 2, up to 2km above sea level

Designed to comply with the following requirements as defined by IEC60664-1: -Reinforced insulation for a primary circuit at a working volatage of 44VAC up to 2km above sea level,

  • Designed to comply with the following requirements as defined by IEC61010-1: -Reinforced insulation for a line to neutral voltage up to 1000Vrms, Overvoltage Category ll, up to 2km above sea level. -Reinforced insulation for a line to neutral voltage up to 600Vrms, Overvoltage Category ll, up to 5km above sea level.
  • Complies with the following requirements as defined by IEC62368-1, UL/CSA62368-1, and EN62368-1: -Reinforced insulation for ES3, operating frequency above 30KHz, working voltage up to 550Vrms, 1600V peak , Overvoltage Category ll, Pollution Degree, and up to 2km above sea level.

Horizontal Installation SMPS Flyback Transformer For CCFL inverter


HOW TO ORDER
1. Please send me the datasheet or part number you need.
2. We will offer the replacement quotation for your reference
3. The free samples are available for your approval.
4. After sample testing, we will step into the mass order.
5. The Proforma Invoice will send for your confirmation
6. After the goods are finished, we send the goods to you and tell you the tracking number.
7. We will track your goods until you receive the goods.

Remarks:
1. Sample orders are available.
2. Price is negotiable for orders of large quantity.
3. Customized orders (OEM/ODM orders) are available.
4. Contact us for the available flavors list. International Certifications:
1. ISO9001:2008
2. UL
3. Reach
4. RoHs

Inquiry Cart 0